C50
Bias (Freq. command 1)
(Bias reference point)
0.00 to 100.00%
0.01
%
Y*
0.00
C51
Bias (PID
(Bias value)
command 1)
(Bias reference
point)
-100.00 to 100.00%
0.01
%
Y*
0.00
C52
0.00 to 100.00%
0.01
%
Y*
0.00
P codes: Motor Parameters
P02
Motor
(Capacity) 0.01 to 10.00kW (when P99 =0.3.4)
0.01 to 10.00 HP (when P99=1)
0.01
0.01
kW
HP
N
Applied
Motor
P03
(Rated current) 0.00 to 99.99A
0.01
A
N
GE Motor
rated
P09
(Slip compensation gain) 0.0 to 200.0%
0.1
%
Y*
0.0
P99
Motor select
0_Motor Specification0 (FUJI 8 Series)
1_Motor Specification1 (HP Motor)
3_Motor Specification3 (FUJI 6 Series)
4_Others
-
-
N
1
H codes: High Performance Functions
H03
Data initializing
(Data reset)
0_Manual set value
1_Return to factory set value
2_Motor parameter initializing (Motor 1)
-
-
N
0
H04
Auto-reset
(Times)
(Reset interval)
0_Inactive
1 to 10 times
0.5 to 20.0s
1
Times
Y
0
H05
0.1
s
Y
5.0
H06
Fan stop operation
0_Inactive
1_Active (1.5kW and above)
-
-
Y
0
H07
ACC/DEC pattern
0_Inactive (linear)
1_S-curve (weak)
2_S-curve (strong)
3_Curvilinear
-
-
Y
0
H12
Instantaneous overcurrent
(Select)
limiting
0_Inactive
1_Active
-
-
Y
1
PTC thermistor
(Select)
(Level)
0_Inactive
1_Active
-
-
Y
0
H27
0.00 to 5.00V
0.01
V
Y
1.60
H30
Serial link
(Function select)
(Monitor) (Hz setting) (OPR command)
0_ Y N N
1_ Y RS485 N
2_ Y N RS485
3_ Y RS485 RS485
-
-
Y
0
H42
Main circuit capacitor meaured
value
Monitoring use
-
H43
Cooling fan accumulated
operation time
Monitoring use and change of cumulative operation time
Y
-
H50
Arbitrary point on (Frequency)
polygonal V/f line
(Voltage)
0.0(cancel) to 400.0 Hz
0.1
Hz
N
0.0
H51
0 to 240V_AVR active (230V class)
0 to 500V_AVR active (460V class)
1
V
N
230
460
H54
ACC/DEC time (Jogging
operation)
0.00 to 3600s
0.01
s
Y
6.00
H64
Low limiter (min. freq. when
current or torque limiting active) 0.0 (Depends on F16_Freq. limiter (Low)) , 0.1 to 60.0Hz
0.1
Hz
Y
2.0
H69
Automatic deceleration
control
(Select)
(Regeneration prevention)
0_Inactive
1_Active
Y
0
H70
Overload prevention control
0.00 (equivalent to DEC time), 0.01 to 100.0Hz/s,
999(cancel)
0.01
Hz/s
Y
999
5-6
StockCheck.com
Содержание Fuji Electric MICRO-SAVER AF-300
Страница 1: ...GEH 6647 AF 300 Mini Startup Guide S t o c k C h e c k c o m ...
Страница 20: ...1 4 Notes S t o c k C h e c k c o m ...
Страница 36: ...2 16 Notes S t o c k C h e c k c o m ...
Страница 56: ...3 20 Notes S t o c k C h e c k c o m ...
Страница 102: ...7 8 Notes S t o c k C h e c k c o m ...
Страница 112: ...8 10 8 4 External Dimensions See dimensions table on next page S t o c k C h e c k c o m ...
Страница 118: ...8 16 Notes S t o c k C h e c k c o m ...
Страница 126: ...10 4 Notes S t o c k C h e c k c o m ...