2-4
2-5
2.3.4 Wiring for Main Circuit Terminals and Ground Terminals
Follow the procedure below. Figure 2.3 illustrates the wiring for peripheral equipment.
Wiring Procedure
(1) Ground terminals G
(2) Drive output terminals (U, V, and W)
(3) DC reactor connection terminals (P1 and P(+))*
(4) Braking resistor connection terminals (P(+) and DB)*
(5) DC link circuit terminals (P(+) and N(-))*
(6) Main circuit power input terminals (L1/R, L2/S and L3/T) or (L1/L and L2/N)
*Wire these as necessary.
Figure 2.3 Wiring Procedure for Peripheral Equipment