![GE Fuji Electric MICRO-SAVER AF-300 Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/ge/fuji-electric-micro-saver-af-300/fuji-electric-micro-saver-af-300_startup-manual_124992045.webp)
3-8
3-9
(4) Jog (Inch) the Motor
In Run mode, pressing the + keys at the same time (simultaneous keying) can make the drive ready for jogging.
The JoG appears on the LED monitor.
To return the drive from the ready-to-jog state to the usual running state, press the + keys simultaneously.
Using the external input signal command (JOG) also allows the transition between the ready-to-jog state and usual
running state.
REFERENCE: Refer to function codes E01 to E03 in Chapter 5 for details.
During jogging, the jogging frequency (C20) and acceleration/deceleration time for jogging (H54) will apply. They are
exclusively prepared for jogging and required to be set up individually.
When jogging the motor from the keypad, the drive will only run while the key is held down, and contrarily the
moment the key is released, the drive will decelerate and stop the motor.
NOTE: The transition ( + keys) between the ready-to-jog state and usual running state is enabled only when the
drive is at a halt.
3.4 Setting the Function Codes – ”Data setting”
Menu #1 “Data setting” in Program mode allows you to set function codes for making the drive functions match
your needs.
The table below lists the function codes available in the AF-300 Mini. The function codes are displayed on the LED
monitor on the keypad as shown below.
Function Code Group
ID number in each function code group
Table 3.5 List of AF-300 Mini Function Codes
Function code group
Function
code
Function
Description
F codes
(Fundamental functions)
F00 to F51
Basic functions To be used for basic motor running.
E codes
(Extension terminal functions)
E01 to E99
Terminal
functions
To be used to select the functions of the control circuit terminals.
To be used to set functions related to the LED monitor display.
C codes
(Control functions of frequency)
C01 to C52
Frequency
control
functions
To be used to set application functions related to frequency
commands.
P codes
(Motor parameters)
P02 to P99
Motor
parameters
To be used to set special parameters for the motor capacity, etc.
H codes
(High performance functions)
H03 to H98
High level
functions
To be used for high added value functions and complicated
control, etc.
J codes
(Application functions)
J01 to J06
Application
functions
To be used for PID control.
y codes
(Link functions)
y01 to y99
Link functions
To be used for communications
REFERENCE: Refer to Chapter 5 “FUNCTION CODES” for details on the function codes.
Function codes that require simultaneous keying
To change data for function codes F00 (Protect data) and H03 (Initialize data), simultaneous keying operation is
necessary-- + keys or + keys. This prevents data from being lost by mistake.
StockCheck.com
Содержание Fuji Electric MICRO-SAVER AF-300
Страница 1: ...GEH 6647 AF 300 Mini Startup Guide S t o c k C h e c k c o m ...
Страница 20: ...1 4 Notes S t o c k C h e c k c o m ...
Страница 36: ...2 16 Notes S t o c k C h e c k c o m ...
Страница 56: ...3 20 Notes S t o c k C h e c k c o m ...
Страница 102: ...7 8 Notes S t o c k C h e c k c o m ...
Страница 112: ...8 10 8 4 External Dimensions See dimensions table on next page S t o c k C h e c k c o m ...
Страница 118: ...8 16 Notes S t o c k C h e c k c o m ...
Страница 126: ...10 4 Notes S t o c k C h e c k c o m ...