8-1
8. Specifications
8.1 Standard Models
1) IP20 type 3-phase 230V/460V series
Item
Specifications
Input power source
3-phase 230V class
3-phase 460V class
Type * * *10
6KXC123____X9 * *: 230V class
6KXC143____X9 * *: 460V class
F12 F25
F50
001
002
003
005
F50
001
002
003 005
Nominal applied motor *1
[hp]
1/8 1/4
1/2
1
2
3
5
1/2
1
2
3
5
[kW]
0.1 0.2
0.4
0.75
1.5
2.2
3.7
0.4
0.75
1.5
2.2 3.7
Output ratings
Rated capacity *2 [kVA] 0.31 0.59
1.1
1.9
3.1
4.3
6.7
1.1
1.9
2.9
4.3 7.1
Rated voltage *3 [V] 3-phase 200V/50 Hz, 200, 220, 230V/60 Hz
3-phase 380,400, 415V/50 Hz, 380, 400,
440, 460V/60 Hz
Rated
current
[A]
High carrier
(4-15 kHz)
0.7 1.4
2.5
4.2
7.0
10.0
16.5
1.5
2.5
3.7
5.5 9.0
Low carrier
(-3 kHz)
0.8 1.5
3.0
5.0
8.0
11.0
17.0
Overload capability
150% of rated current for 1 min, 200% of rated current for 0.5 s
Rated frequency
50, 60 Hz
Input ratings
Phase, voltage, frequency
3-phase, 200 to 240V, 50/60 Hz
3-phase, 380 to 480V, 50/60 Hz
Voltage/frequency variations
Voltage: +10 to -15% (Voltage unbalance *8: 2% or less) Frequency: +5 to -5%
Momentary voltage dip
capability *4
As long as input voltage is 165V or above the drive
continues operation. If it drops below 165V, the drive
operates for 15 ms.
As long as input voltage is 300V or more,
the drive continues operation. If it drops
below 300V, the drive operates for 15 ms.
Rated current
(with DCR)
0.57 0.93
1.6 3.0
5.7
8.3
14.0
0.85
1.6
3.0
4.4 7.3
*9 [A]
(without DCR) 1.1 1.8
3.1 5.3
9.5
13.2
22.2
1.7
3.1
5.9
8.2 13.0
Required power supply
0.3 0.4
0.6 1.1
2.0
3.0
4.9
0.6
1.1
2.0
2.9 4.9
Capacity *5
[kVA]
Braking
Torque *6
[%]
150
100
50
30
100
50
30
Torque *7
[%]
-
150
150
DC injection braking
Starting frequency: 0.0 to 60.0 Hz, braking time: 0 to 30.0 s, braking level: 5 to 100% of rated current
Conformity to safety standards
UL508C, C22.2No.14, EN50178:1997
Enclosure (IEC60529)
IP20
Cooling method
Natural cooling
Fan cooling
Natural cooling
Fan cooling
Weight
[lbs]
1.3 1.3
1.3
1.5
3.7
3.7
5.1
2.4
2.6
3.7
3.7
5.1
*1) GE 4-pole standard motor
*2) Drive output capacity (kVA) at 230V/460V
*3) Output voltage cannot exceed the power supply voltage.
*4) Tested under standard conditions with 85% nominal motor load.
*5) Obtained with a dc reactor.
*6) Average braking torque with AVR control OFF (varies with motor efficiency.)
*7) Average braking torque using external braking resistor (optional)
No braking resistor is available for 1/8 hp, 1/4 hp.
*8) Voltage unbalance [%] = (Max voltage [V] - Min voltage [V]) / 3-phase average voltage [V] x 67 (IEC61800-3 (5.2.3)) If this
value is 2 to 3%, use ac reactor (option).
*9) Calculated under GE Fuji specified conditions.
*10) Indicates product revision.
StockCheck.com
Содержание Fuji Electric MICRO-SAVER AF-300
Страница 1: ...GEH 6647 AF 300 Mini Startup Guide S t o c k C h e c k c o m ...
Страница 20: ...1 4 Notes S t o c k C h e c k c o m ...
Страница 36: ...2 16 Notes S t o c k C h e c k c o m ...
Страница 56: ...3 20 Notes S t o c k C h e c k c o m ...
Страница 102: ...7 8 Notes S t o c k C h e c k c o m ...
Страница 112: ...8 10 8 4 External Dimensions See dimensions table on next page S t o c k C h e c k c o m ...
Страница 118: ...8 16 Notes S t o c k C h e c k c o m ...
Страница 126: ...10 4 Notes S t o c k C h e c k c o m ...