13.1.1.1 Edit/New
Choose the
icon to edit existing entries. Choose the Newbutton to create application
level gateway entries.
Fig. 156:
VoIP
->
Application Level Gateway
->
SIP Proxies
->
Edit/New
The VoIP->Application Level Gateway -> SIP Proxies -> Edit/New menu, consists of the
following fields:
Fields in the SIP Proxies Basic Parameters menu
Field
Description
Description
Enter the name of the application level gateway.
Administrative Status
Select whether the SIP proxy should be enabled or disabled.
The function is activated by choosing
Enabled
.
The function is enabled by default.
Protocol
Select the protocol to be used.
Possible values:
UDP
(default value) or
TCP
.
Under Destination Port enter the port to be supervised by the
proxy.
or each destination port to which VoIP clients from the LAN can
connect, you must configure a proxy.
Funkwerk Enterprise Communications GmbH