Field
Value
to a request. If an answer has still not been received after these
attempts, the Status is set to
down
. If the Active Check =
En-
abled
your device tries to reach the server every 20 seconds. If
the server answers, the Status is set back to
alive
.
Possible values are whole numbers between
0
and
10
.
The default value is
1
. To prevent Status being set to
down
, set
this value to
0
.
RADIUS Dialout
Only for Authentication Type =
Authentication
and
IPSec
Authentication
.
Select whether your device receives requests from RADIUS
server dialout routes. This enables temporary interfaces to be
configured automatically and your device can initiate outgoing
connections that are not configured permanently.
The function is activated by choosing
Enabled
.
The function is disabled by default.
If the function is active, you can enter the following options:
•
Reload Interval
Enter the time period in seconds
between the update intervals.
The default entry here is
0
i.e. an automatic reload is not car-
ried out.
•
Default User Password
: This is the shared password
used for communication between the RADIUS server and
your device.
5.5.2
permits access control for your device, network access servers (NAS) and other
network components via one or more central servers.
Like RADIUS, is an AAA protocol and offers authentication, authorisation and
accounting services ( Accounting is currently not supported by bintec devices).
The following functions are available on your device:
• Authentication for login shell
Funkwerk Enterprise Communications GmbH
5 System management
bintec R1xxx/R3xxx/R4xxx
151