Field
Description
•
115200 bps
: Recommended for communication with an ana-
logue modem.
Incoming Service Type
Here you select the gateway subsystem to which an incoming
call over the modem is to be assigned.
Possible values:
•
Disabled
: No call is accepted.
•
ISDN Login
(default value): The call is assigned to the
ISDN Login subsystem.
•
PPP Dialin
: The call is assigned to the PPP subsystem.
SIM Card Uses PIN
Here you enter the PIN of your GSM modem, if your modem
asks for it.
Entering a wrong PIN blocks communication with the modem
until the entry in the profile is corrected.
Modem Escape Charac-
ter
The value for this field is set by default to
+
. It should only be
changed if the escape character of the modem is different.
Modem Init Sequence
Here you can enter an initialization string for your modem. The
command ATX3&K3\V1 is the default setting (the modem does
not wait for a free signal before dialling).
You can add other AT commands by separating them with
semicolons. The entry is limited to 50 characters. Make sure
you enter the command for activating the XON/XOFF software
flow control. This is proprietary and cannot be set automatically.
The command sequence can be obtained from your modem
manual or the manufacturer.
APN (Access Point
Name)
If GPRS is used, the so-called Access Point Name of the pro-
vider must be entered, e.g. internet.eplus.de for eplus and so
on.
A maximum of 40 characters can be entered. If no APN or an
incorrect APN is entered, a configured GPRS connection will
not function.
6 Physical interfaces
Funkwerk Enterprise Communications GmbH
158
bintec R1xxx/R3xxx/R4xxx