Field
Description
Source IP Address
Select how the IP address is to be determined that your device
uses as the source address of the packet sent to the host to be
monitored.
Possible values:
•
Automatic
(default value): The IP address is determined
automatically.
•
Specific
: Enter the IP address in the adjacent input field.
Interval
Enter the time interval (in seconds) to be used for checking the
availability of hosts.
Possible values are
1
to
65536
.
The default value is
10
.
The smallest Interval of the group members is used within a
group.
Trials
Enter the number of pings that must remain unanswered for the
host to be regarded as unavailable.
Possible values are
1
to
65536
.
The default value is
3
.
Controlled interfaces
Select the interface(s) for which the action defined in Interface
Action is to be performed.
All physical and virtual interfaces can be selected.
Each interface, select whether each interface is to be activated (
Enable
) or deactivated (
Disable
, default value).
Funkwerk Enterprise Communications GmbH
14 Local services
bintec R1xxx/R3xxx/R4xxx
451