Assembly Stage Three: Connect the Water Pump
Your HL405g laser uses a watercooled continuous beam CO2 laser tube. The tube requires a
flow of room temperature water to regulate the temperature of the resonance chamber. Your
purchase includes a water pump for cooling the laser tube.
NEVER FIRE THE LASER WITHOUT A CORRECTLY CONNECTED AND
POWERED WATER PUMP. FIRING THE LASER WITHOUT TURNING THE
PUMP ON OR, WORSE, WITH NO WATER IN THE SYSTEM, WILL
SEVERELY DEGRADE OR DESTROY YOUR LASER TUBE AND VOID
YOUR WARRANTY.
CONNECTING THE WATER PUMP STEPS:
1. Remove Capping On Water inlet/Outlet.
Remove the short silicone tubing capping the
water inlet and outlet on the back of the machine.
.
2. Attach Water Pump FItting.
Remove the water pump (D) from its packaging. Attach the
white plastic fitting (C) to the water pump by gently screwing it on.
3. Prep Water Bucket.
Fill a clean 5 gallon bucket (not included) with 3 4 gallons of distilled
water (not included). ALWAYS use only distilled water and replace often.
4. Attach Inlet Water Tubing.
Push one end of one of the two (2) silicone water tubes (E)
onto the water pump fitting (C). Now attach the other end of that tubing to the “water inlet”
located at the back of machine. Completely submerge the assembled water pump in the
bucket of distilled water.
Technical Support is available from 8:00 am (PST) to 5:00 pm (PST) Monday through Friday at
.