9
Electrical Safety
The power supply is capable of outputting DC 20,000V at up to 20mA—always make sure to give
the supply capacitors adequate time to discharge before accessing the electronics area. This
power is also provided to the discharge terminals on the laser tube itself. Your laser shipped with
silicone terminal covers that prevent access to bare wiring—notify Full Spectrum Laser support and
immediately cease operations if these covers ever slip and expose bare wir
e.
DO NOT
open any of the machine’s access panels while the unit is plugged in. Opening a panel
may expose the operator to the unit’s AC input power. The AC input power is potentially lethal and
is located on the far right within the cabinet.
NEVER
make or break any electrical connections to the system while the unit is turned on.
NEVER
access the electronics area with hands or tools unless the unit is disconnected from power
for at least one hour.
NEVER
replace the installed 10 amp fuse with a fuse of a higher rating. This will void your warranty
and the electronics will not be adequately protected from surges or short circuits.
POWER ON/OFF
is controlled by the large red button (estop) located on the top of the case in the
far right. This is a normallyopen twist to release button. To power the laser down, simply press the
button down until it locks. To power the laser up, twist the button clockwise according to the
indicating arrows on the surface of the button.
IN CASE OF A BLOWN FUSE
determine the cause of the overload before replacement to protect
the machine from damage.
Technical Support is available from 8:00 am (PST) to 5:00 pm (PST) Monday through Friday at
.