background image

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly 

maintained, give you years of trouble free performance.

  1.  SAFETY INSTRUCTIONS

1.2. 

GENERAL SAFETY

 

WARNING!

 Disconnect the cut-off machine from the mains power, and ensure that the cutting disc is at a complete standstill before    

 

attempting to change accessories, service or perform any maintenance.

 

Maintain the cut-off machine in good condition (use an authorised service agent).

 

Replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

Locate the cut-off machine in a suitable work area. Ensure that the surface is flat and firm. Keep the area clean and tidy and free from  

 unrelated materials, and ensure that there is adequate lighting.

 

Keep the cut-off machine clean for best and safest performance and check moving parts alignment regularly. 

 

WARNING!

 Before each use check that the cutting disc is secure and that it is not worn or damaged.

 

NOTE:

 Only competant persons should attempt to change cutting discs.

 

Ensure that replacement discs are not damaged in any way - cracks or deformations etc. Also check the mounting flanges to check that  

 

they are not deformed, burred or chipped.

 DO NOT

 over tighten a disc and never tamper with a disc in order to adapt it to a different   

 

size holder.

 

Always use a disc suitable for the material being cut. Ensure that the cutting disc's specified maximum speed is equal to, or higher    

 

than, that indicated on the machine data plate. Once mounted on the cut-off machine, test the disc before use by facing the cut-off    

 

machine in a safe direction (point disc away from yourself, others and vulnerable items) and running it for a short time. 

 

WARNING!

 Keep guard and holding screws in place, tight and in good working order. Check regularly for damaged parts. 

 

A guard or any other part that is damaged must be repaired or replaced before next use. The safety guard is a mandatory fitting when  

 

the cut-off machine is used on premises covered by the Health & Safety at Work Act.

 

Remove adjusting keys and wrenches from the machine and its vicinity before turning it on.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. 

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE 

AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

SM150D    Issue: 3(SP) 10/12/13

1.1. 

ELECTRICAL SAFETY

 

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

 

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and    

 

any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of  

 

 

appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also  

 

recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are    

 

plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual    

 

Current Device by contacting your Sealey dealer. 

 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances    

 

and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.    

 

and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or damage and check all connections  

 

 

to ensure that none is loose.

1.1.6.  Important: Ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT

 pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is  

 

 

 

damaged, cut the cable just above the plug and dispose of the plug safely. 

 

Fit a new plug according to the following instructions (UK only).

 

a)

 

Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b)

 

Connect the BROWN live wire to the live terminal ‘L’. 

 

 

 

 

c)

 

Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d)

 

After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation  

 

   

extends beyond the cable restraint and that the restraint is tight.

 

Double insulated

 products, which are always marked with this symbol  , are fitted with live (brown) and neutral (blue) wires only. 

 

To rewire, connect the wires as indicated above - 

 

DO NOT connect either wire to the earth terminal.

1.1.10.  Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure that  

 

a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your  

 electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance    

 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm

2

, but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use   

 

of 2.5mm

2

 section cable.

Original Language Version

© Jack Sealey Limited

RECOMMENDED

FUSE RATING 13AMP

INSTRUCTIONS FOR:

CUT-OFF MACHINE 150MM 230V WITH DISC

MODEL No

SM150D

Содержание SM150D

Страница 1: ...Current Device RCD is used It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB If in any doubt consult a qualified electrician You may obtain a Residual Current Device by contacting your Sealey dealer You must also read and understand the following instructions concerning electrical safety 1 1 1 The Electricity at Work ...

Страница 2: ...machine if any parts are missing or damaged as this may cause failure and or personal injury DO NOT remove the safety guard whilst the cut off machine is in use DO NOT attempt to remove a workpiece until the disc has stopped rotating DO NOT touch the workpiece close to the cut as it will be very hot Allow to cool The cut edge of the workpiece will also be very sharp DO NOT leave the cut off machin...

Страница 3: ...re attempting to lower the cutting edge onto the workpiece 4 5 2 Lower the cutting disc slowly and smoothly down towards the workpiece avoid jerky movements 4 5 3 Avoid subjecting the disc to excessive strain Always ease the disc down against the workpiece a harsh downward impact may cause disc failure and do not apply undue force on the handle when cutting the workpiece Maintain a controlled cutt...

Страница 4: ...iness Park Bury St Edmunds Suffolk IP32 7AR www sealey co uk W e b email NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of this product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim INFO...

Отзывы: