Chapter 5 RAID Group Management
5.7 Assign Eco-mode Schedule (RAID Group)
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
549
For details on the parameters for this function, refer to
"A.5.6 Assign Eco-mode Schedule (RAID Group)" (page
.
For the factory default settings for this function, refer to
"Appendix B Assign Eco-mode Schedule (RAID Group)"
The procedure to set Eco-mode schedule for the RAID group is as follows:
Procedure
1
Select the RAID group to assign the Eco-mode schedule (multiple selections can be made)
to and click [Assign Eco-mode] in [Action].
2
Select the Eco-mode schedule that is to be assigned and select the Eco-mode action.
The main setting items are as follows.
●
Eco-mode Schedule Setting
•
Eco-mode Schedule
•
Eco-mode Action
•
Before applying Eco-mode for RAID groups, use the procedure in
"1.6.1 Modify Eco-mode General Setting"
to enable the Eco-mode setting for the ETERNUS DX S3 series.
•
Set the Eco-mode schedule using the procedure in
"1.6.4 Modify Eco-mode Schedule" (page 80)
•
When selecting multiple RAID groups as the target of the Eco-mode, the same Eco-mode schedule can be
specified for all the selected RAID groups.
•
RAID groups that configure a WSV can be checked in the [Volume Detail] screen. Refer to "Volume Details
(Used RAID Group)" in "ETERNUS Web GUI User’s Guide (Operation)" for details.
•
To use Eco-mode for RAID groups registered in Thin Provisioning Pools, assign the Eco-mode schedule to
the Thin Provisioning Pools. Refer to
"6.10 Assign Eco-mode Schedule (Thin Provisioning Pool)" (page
for details.
•
Note that Eco-mode cannot be set to RAID groups registered in the FTSP.