Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
739
•
FC CA Port Link Status Changed
•
Host Login Over
•
NAS Connection Status
•
Out of NAS Capacity
Description
Select whether to notify when a link down occurs after an FC link is established and the
link status is changed. When notifying, select the notification method.
Note that a change in the link status due to user operation is not notified.
A change in the link status for all the FCs is notified. The notification is reported
regardless of the type (FC), the port mode (CA, RA, CA/RA, Initiator), and the transfer
rate. The following FC link status types can be detected and notified:
•
The link status between the ETERNUS DX and a directly connected server
•
The link status between the ETERNUS DX and switches
The FC link status can be checked in the [Port Detail] screen. Refer to "Channel Adapter"
in "ETERNUS Web GUI User’s Guide (Operation)" for details.
•
Only the FC link status is notified. Note that a change in link status for iSCSI, SAS, and FCoE is not notified.
•
Link up and link down that occur due to the following user operations are not notified.
-
Rebooting of the ETERNUS DX
-
Hot maintenance of a CA or a CM in which a CA is installed
-
Preventive maintenance of a CA or a CM in which a CA is installed
-
Chip reset due to a change in the FC port parameters
•
If the occurrence of link down and link up repeats within a 10 second interval, the first two sets of link down and
link up are notified. Notification of this event is suspended for 20 minutes after the notification.
•
Note that the link status between a server and a switch cannot be detected.
Description
Select whether to notify when the number of connected hosts for each CA port exceeds
the maximum value (256 hosts). When notifying, select the notification method.
This item is notified regardless of the CA type (FC, iSCSI, SAS, and FCoE).
Description
Select whether to notify when the link status for a NAS connection is changed (such as
mount, unmount, or recovery of the file system) in the NAS system. When notifying,
select the notification method.
This item is only displayed in a Unified Storage environment.
Description
Select whether to notify when insufficient capacity in the file system (data area) that is
allocated by the NAS is detected in the NAS system. When notifying, select the
notification method.
This item is only displayed in a Unified Storage environment.
Содержание Eternus DX200F
Страница 2: ...This page is intentionally left blank ...
Страница 1082: ......