Chapter 4 Connectivity Management
4.3 CA Port Group Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
437
2
Specify the name of the port group to be created, select all the ports to be registered in the
port group.
The main setting items are as follows.
●
CA Port Group Setting
•
Name
•
Checkbox to select ports
3
Click the [Create] button.
A confirmation screen appears.
4
Click the [OK] button.
Registration of the FCoE port group starts.
5
Click the [Done] button to return to the [CA Port Group] screen.
End of procedure
If an error screen appears under the following conditions, check the parameter settings.
•
The "Name" is not entered
•
The "Name" does not satisfy the input conditions
•
The "Name" overlaps with an existing port group name
(port group names cannot overlap with any other port group names, irrespective of the CA types.)
•
The total number of port groups has exceeded the maximum number for the ETERNUS DX
•
Nine or more ports are registered in the port group or no ports are registered in the port group
•
Ports with the affinity mode enabled (On) and disabled (Off) exist together