Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
729
•
Display drives with warning status on LCD
●
Error Severity Level
Select whether to notify an error event for each event type.
The input conditions and the display contents for the error severity level are as follows:
•
Parts Error
•
Drive Error
Description
Select whether to display the drive warning message on the LCD. This is displayed
only for the ETERNUS DX8700 S3/DX8900 S3.
•
Any Time
Select "Enable" when displaying the drive warning message on the LCD at any time
regardless of whether the hot spare disk exists, or select "Disable" if the message
should not be displayed.
•
when HS<0
Select "Enable" when displaying the drive warning message only if a drive warning
occurs when the available hot spare disk is "0", or select "Disable" if the message
should not be displayed. This item can be selected only when the "Display drives with
warning status on LCD (Any Time)" checkbox is cleared.
Input condition/
Display contents
•
Any Time
-
Enable
-
Disable
•
when HS<0
-
Enable
-
Disable
Input condition/
Display contents
Checkbox
•
Selected
Notify
•
Cleared
Not notify
•
-
Not applicable to notification
Description
Select whether to notify when a failure occurs in a part other than the drive. When
notifying, select the notification method.
Description
Select whether to notify when a failure occurs in a non-protected (non-shielded) drive
for each condition that is described below. When notifying, select the notification
method.
•
Any Time
Notifies always when a drive failure occurs.
•
when HS<0
Notifies only when a drive failure occurs while available hot spare disk is " 0" (*1).
*1:
When rebuilding cannot be performed because there are no hot spares that can be
used as a substitute for the failed drive.