Chapter 6 Thin Provisioning Pool Management
6.2 Create Thin Provisioning Pool
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
562
3
Click the [Create] button
A confirmation screen appears.
4
Click the [OK] button.
Create Thin Provisioning Pool starts.
5
Click the [Done] button to return to the [Thin Provisioning Pool] screen.
End of procedure
•
When using SSDs, the SSD types (SSD-M/SSD) cannot be specified. SSDs that are the same type
and have the necessary capacity in a RAID group to create TPPs are selected. If the number of SSDs
with the same type is insufficient for configuring a RAID group, a TPP is not created. In this case,
reduce the total capacity of the TPP. If multiple RAID groups are created in a TPP, different SSD
types may be used for the RAID groups. SSD types have no order of priority.
•
When SSD-Ms with an interface speed of 12Gbit/s are installed in a high-density drive enclosure,
the SSDs operate at 6Gbit/s because the interface speed of the high-density drive enclosure is
6Gbit/s. When 12Gbit/s SSD-Ms are installed in the high-density drive enclosure, select the drives
manually. If drives are automatically selected from SSDs that are from the high-density drive
enclosures, or from both the high-density drive enclosures and other drive enclosures, all SSDs
operate at 6Gbit/s.
•
If "High Performance (RAID1+0)" or "High Capacity (RAID5)" is selected for the RAID level, RAID
groups cannot be created with drives that are 6TB or larger (except SSDs and SSD SEDs).
•
If an error screen appears under the following conditions, check the parameter settings.
-
When the "Name" field is not input
-
When the "Name" does not satisfy the input conditions
-
When the "Name" already exists
-
When the "Thin Provisioning Pool Total Capacity" field is not input
-
When the total value of TPP capacity to be created and existing pool capacity exceeds the
maximum pool capacity for each model
-
When a TPP that meets the specified conditions (drive type, RAID level, and capacity that is
equal to or larger than the specified value) cannot be created with the installed drives in the
ETERNUS DX
•
Specify the threshold so that "Warning" is the same or larger than "Attention".
•
The "Attention" threshold can be omitted. When setting the "Attention" threshold, specify a
threshold while the checkbox is selected.