![FOTEK GD20-004G-2 Скачать руководство пользователя страница 80](http://html.mh-extra.com/html/fotek/gd20-004g-2/gd20-004g-2_operation-manual_2324086080.webp)
Goodrive20 Series VFD
Function parameter list
-75-
Function
code
Name
Description
Default
Modify
P07.53
Bus voltage at the last but one faults
0.0V
●
P07.54
Max. temperature at the last but one faults
0.0°C
●
P07.55
Input terminal state at the last but one faults
0
●
P07.56
Output terminal state at the last but one faults
0
●
P08 group Enhanced functions
Function
code
Name
Description
Default
Modify
P08.00
ACC time 2
Refer to
P00.11
and
P00.12
for detailed
definition.
The VFD has four groups of ACC/DEC
time which can be selected by P5 group.
The first group of ACC/DEC time is the
factory default one.
Setting range: 0.0
–3600.0s
Depend
on model
○
P08.01
DEC time 2
Depend
on model
○
P08.02
ACC time 3
Depend
on model
○
P08.03
DEC time 3
Depend
on model
○
P08.04
ACC time 4
Depend
on model
○
P08.05
DEC time 4
Depend
on model
○
P08.06
Running
frequency
of jog
The function code is used to define the
reference frequency during jogging.
Setting range: 0.00Hz
–
P00.03
(max.
output frequency)
5.00Hz
○
P08.07
ACC time for
jog
ACC time for jogging means the time
needed for the VFD to accelerate from
0Hz to the max. output frequency
(
P00.03
).
DEC time for jogging means the time
needed for the VFD to decelerate from the
max. output frequency (
P00.03
) to 0Hz.
Setting range: 0.0
–3600.0s
Depend
on model
○
P08.08
DEC time for
jog
Depend
on model
○
P08.09
Jump
frequency 1
When the set frequency is within the range
of jumping frequency, the VFD runs at the
boundary of jumping frequency.
The VFD can avoid the mechanical
resonance point by setting jumping
0.00Hz
○
P08.10
Jump
frequency
amplitude 1