![FOTEK GD20-004G-2 Скачать руководство пользователя страница 106](http://html.mh-extra.com/html/fotek/gd20-004g-2/gd20-004g-2_operation-manual_2324086106.webp)
Goodrive20 Series VFD
Function parameter list
-101-
P17 group Status viewing
Function
code
Name
Description
Default Modify
P17.00
Set
frequency
Displays current set frequency of the VFD.
Range: 0.00Hz
–
P00.03
●
P17.01
Output
frequency
Displays current output frequency of the
VFD.
Range: 0.00Hz
–
P00.03
●
P17.02
Ramp
reference
frequency
Displays current ramp reference frequency
of the VFD.
Range: 0.00Hz
–
P00.03
●
P17.03
Output
voltage
Displays current output voltage of the VFD.
Range: 0
–1200V
●
P17.04
Output
current
Displays the valid value of present output
current of the VFD.
Range: 0.0
–5000.0A
●
P17.05
Motor
speed
Displays current motor speed.
Range: 0
–65535RPM
●
P17.06
Torque
current
Displays current torque current of the VFD.
Range: 0.0
–5000.0A
●
P17.07
Exciting
current
Displays current exciting current of the VFD.
Range: 0.0
–5000.0A
●
P17.08
Motor
power
Displays current motor power; 100% relative
to rated motor power, positive value is
motoring state, negative value is generating
state.
Setting range: -300.0%
–300.0% (relative to
rated motor power)
●
P17.09
Output
torque
Displays current output torque of the VFD;
100% relative to rated motor torque, positive
value is motoring state, negative value is
generating state.
Range: -250.0
–250.0%
●
P17.10
Estimated
motor
frequency
Displays the estimated motor rotor frequency
under open-loop vector condition.
Range: 0.00
–
P00.03
●
P17.11
DC bus
voltage
Displays current DC bus voltage of the VFD
Range: 0.0
–2000.0V
●