Function
code
Name
Description
Default
Modify
P06.17
Lower limit
of AO1
output
The function codes define the relationship
between the output value and analog output.
When the output value exceeds the allowed
range, the output uses the lower limit or
upper limit.
When the analog output is current output, 1
mA equals to 0.5 V.
In different cases, the corresponding analog
output of 100% of the output value is
different.
10V (20mA)
0.0%
100.0%
AO
Setting range of
P06.17
: -100.0%
–
P06.19
Setting range of
P06.18
: 0.00V
–10.00V
Setting range of
P06.19
:
P06.17
–100.0%
Setting range of
P06.20
: 0.00V
–10.00V
Setting range of
P06.21
: 0.000s
–10.000s
Setting range of
P06.22
: -100.0%
–
P06.24
Setting range of
P06.23
: 0.00V
–10.00V
Setting range of
P06.24
:
P06.22
–100.0%
Setting range of
P06.25
: 0.00V
–10.00V
Setting range of
P06.26
: 0.000s
–10.000s
0.0%
○
P06.18
Correspond
ing AO1
output to
the lower
limit
0.00V
○
P06.19
Upper limit
of AO1
output
100.0%
○
P06.20
The
correspondi
ng AO1
output to
the upper
limit
10.00V
○
P06.21
AO1 output
filter time
0.000s
○
P06.22
Lower limit
of AO2
output
0.0%
○
P06.23
Correspond
ing AO2
output to
the lower
limit
0.00V
○
P06.24
Upper limit
of AO2
output
100.0%
○
P06.25
Correspond
ing AO2
output to
the upper
limit
10.00V
○
P06.26
AO2 output
filter time
0.000s
○