![FOTEK GD20-004G-2 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/fotek/gd20-004g-2/gd20-004g-2_operation-manual_2324086025.webp)
Goodrive20 Series VFD
Installation guidelines
-20-
Type
Terminal
name
Function description
Technical specifications
supply of digital input and output or
external sensor power supply.
Analog
input/output
+10V
External 10V
reference power
supply
10V reference power supply;
Max. output current: 50 mA;
As the adjusting power supply of the
external potentiometer;
Potentiometer resistance: 5
kΩ above.
AI2
Analog input
1. Input range: AI2 voltage and current
can be chosen: 0
–10V/0–20mA; AI3:
-10V
–+10V.
2. Input impedance: voltage input:
20kΩ; current input: 500Ω.
3. Voltage or current input can be set by
dip switch.
4. Resolution: the minimum AI2/AI3 is
10mV/20mV when 10V corresponds to
50Hz.
AI3
GND
Analog reference
ground
Analog reference ground
AO1
Analog output
1. Output range: 0
–10V or 0–20mA.
2. The voltage or the current output is
depended on the dip switch.
3. Deviation±1%, 25°C when full range.
AO2
Relay output
RO1A
Relay 1 NO contact Relay output RO1
RO1A is in the NO state, RO1B is in the
NC state, and RO1C is the common
terminal.
Relay output RO2
RO2A is in the NO state, RO2B is in the
NC state, and RO2C is the common
terminal.
Contact capacity: 3A/AC 250V
RO1B
Relay 1 NC contact
RO1C
Relay 1 common
contact
RO2A
Relay 2 NO contact
RO2B
Relay 2 NC contact
RO2C
Relay 2 common
contact
3.2.6 Input/output signal connection figure
You can select the NPN/PNP mode and internal/external power through the U-type short
connector. NPN internal mode is adopted by default.