53
Service setting manual
EN
Para-
meter
Parameter name
Parameter description
Setting range
Default
setting
S3.14
LIMITATION
OF TEMP.
DIFFERENCE
BETWEEN
STAND AND
RETURN PIPE
Setting of maximal difference be-
tween stand-pipe and return-pipe
temperature. This way the highest
power of heating system is limited.
Limitation of difference between
stand and return pipe is activated
with parameter S1.5=3.
3 ÷ 30 °C
10
S3.15
CONSTANT
STAND-PIPE
TEMPERATURE
Selection of operation with constant
stand-pipe temperature.
Setting range is 10 ÷ 140 °C.
CAUTION:
This function deactivates
weather compensated control of
mixing valve.
0- NO
1- YES
0
S3.16
CIRCULATION
PUMP
SWITCH-OFF
DELAY
Setting of circulation pump
switch-off delay when there is
no requirement for heating.
0 ÷ 10 min
5
Para-
meter
Parameter name
Parameter description
Setting range
Default
setting
S4.1
OUTPUT R5
FUNCTION
Setting of output R5 alternative
operation mode.
1- operation according to selected
hydraulic scheme
2- d. h. w. warming with electric
heater
3- operation according to selected
program timer for d. h. w. warming.
4- control of primary boiler pump
5- output is used for d. h. w.
circulation.
6- d. h. w. warming without temp.
difference (by warming with heat
pump).
1- SCHEME
2- EL. HEATER
3- PROG.
TIMER
4- PRIM. PUMP
5- CIRCULA-
TION
6- WITHOUT
DIFF.
1
S4.2
HYSTERESIS
FOR D. H. W.
WARMING
Setting of difference between
switch-on and switch-off point for
domestic hot water warming.
2 ÷ 20 °C
4
SERVICE SETTINGS FOR DOMESTIC HOT WATER
SERVICE PARAMETERS
Содержание MeiTronic W10
Страница 1: ...DE DE W10B W10 W20 Weather compensated heating controller Witterungsgef hrte Heizungsregler...
Страница 2: ......
Страница 98: ...98 Statements EN...
Страница 230: ...230...
Страница 231: ......