36
Service setting manual
EN
USER PARAMETERS
Para-
meter
Parameter name
Parameter description
Setting range
Default
setting
P1.1
AUT.
SWITCHOVER
SUMMER /
WINTER
Automatic switch-off and switch-on
of heating in respect to average
one-day outdoor temperature.
0- NO
1- YES
1
P1.2
AVERAGE
OUTDOOR
TEMP. FOR
SUMMER
/ WINTER
SWITCHOVER
Setting of average one-day outdoor
temperature at which the heating
should switch-off or switch-on.
10 ÷ 30 °C
18
P1.3
OUTDOOR
TEMP. FOR
ACTIVATION
OF FROST
PROTECTION
Setting of outdoor temperature
by which the frost protection will
activate and run boiler at minimum
temperature.
-30 ÷ 10 °C
2
P1.4
REQUESTED
ROOM TEMP.
WHEN
HEATING IS
SWITCHED
OFF
Setting of requested room
temperature when heating is
switched off.
2 ÷ 12 °C
6
P1.5
TEMPERATURE
ROUND UP
Precision of displayed temperatures. 0- 0.1 °C
1- 0.2 °C
2- 0.5 °C
3- 1 °C
2
P1.6
AUT. SHIFT
OF CLOCK
TO SUMMER /
WINTER TIME
With the help of a calendar, the
controller carries out the automatic
clock changeover between summer
and winter time.
0- NO
1- YES
1
P1.7
PERIOD OF
TEMPERAT.
LOGGING
By setting this field you define how
often the measured temperatures are
saved.
1 ÷ 30 min
5
P1.8
TONES
By setting this field you define
whether key pressing is accompanied
with sound signals or not.
0- OFF
1- KEYPAD
2- ERRORS
3- KEYPAD &
ERRORS
1
GENERAL SETTINGS
Содержание MeiTronic W10
Страница 1: ...DE DE W10B W10 W20 Weather compensated heating controller Witterungsgef hrte Heizungsregler...
Страница 2: ......
Страница 98: ...98 Statements EN...
Страница 230: ...230...