6
Positioning mode
94
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
Timing diagram: cancel homing through error message
Start positioning
(DIN8)[X1.23]
Stop
(DIN13)[X1.15]
Limit switch 0
(DIN6)[X1.22]
Limit switch 1
(DIN7)[X1.10]
Motion complete
(DOUT1)[X1.12]
Controller ready for operation
(DOUT0)[X1.24]
Common error
(DOUT3)[X1.13]
t1
t3
t2
“Search”
Error
Status word referenced (FCT)
Homing carried out
(DOUT…)[X1.…]
Speed
v+
v–
3
1
2
t1
≤
5 ms
t2
= … ms (dependent on the acceleration
ramp)
t3
= … ms (dependent on the configuration
“error function” in the error management and
the corresponding parameter in the stop
deceleration)
1
Example: “normally closed” limit switch type
2
Travel curve with “Positive limit switch”
homing methods
3
Travel curve with “Negative limit switch”
homing methods
Fig. 6.25 Timing diagram: cancel homing through error message (e.g. following error, …)