![Festo CMMS-AS-G2 Series Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130151.webp)
A
Diagnostic messages
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
151
Error group 22
PROFIBUS
No.
Reaction
Message
Code
22-2
7500h
PROFIBUS communication error
PS off
Cause
–
Faulty initialisation of the PROFIBUS interface.
–
Interface defective.
Measure
•
Check the set slave address.
•
Check bus termination.
•
Check wiring.
Error group 25
Firmware
No.
Code
Message
Reaction
25-1
6081h
Incorrect firmware
PS off
Cause
Motor controller and firmware are not compatible.
Measure
•
Update the firmware.
Error group 26
Data flash
No.
Code
Message
Reaction
26-1
5581h
Checksum error
PS off
Cause
Checksum error of a parameter set.
Measure
•
Load factory setting.
•
If the error is still present, the hardware may be defective.
Error group 29
SD card
No.
Code
Message
Reaction
29-0
7680h
No SD available
Configurable
Cause
An attempt was made to access a missing SD card.
Measure
Check:
•
whether the SD card is inserted properly,
•
whether the SD card is formatted,
•
whether a compatible SD card is plugged in.
29-1
7681h
SD initialization error
Configurable
Cause
–
Error during initialization.
–
Communication not possible.
Measure
•
Plug card back in.
•
Check card (file format FAT 16).
•
If necessary, format card.