![Festo CMMS-AS-G2 Series Скачать руководство пользователя страница 153](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130153.webp)
A
Diagnostic messages
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
153
Error group 35
Fast stop
No.
Code
Message
Reaction
35-1
6199h
Time out for fast stop
PS off
Cause
The parametrised time for fast stop was exceeded.
Measure
•
Check parameterisation.
Error group 40
Software end position
No.
Code
Message
Reaction
40-0
8612h
Negative software limit switch reached
Configurable
Cause
The position setpoint has reached or exceeded the negative soft-
ware limit switch.
Measure
•
Check the target data.
•
Check positioning area.
40-1
8612h
Positive software limit switch reached
Configurable
Cause
The position setpoint has reached or exceeded the positive soft-
ware limit switch.
Measure
•
Check the target data.
•
Check positioning area.
40-2
8612h
Target position lies behind the negative software limit switch
Configurable
Cause
Start of a positioning task was suppressed because the target lies
behind the negative software limit switch.
Measure
•
Check the target data.
•
Check positioning area.
40-3
8612h
Target position lies behind the positive software limit switch
Configurable
Cause
The start of a positioning task was suppressed because the target
lies behind the positive software limit switch.
Measure
•
Check the target data.
•
Check positioning area.
Error group 41
Path program
No.
Code
Message
Reaction
41-8
6193h
Path program error, unknown command
Configurable
Cause
Unknown command found during record continuation.
Measure
•
Check parameterisation.
41-9
6192h
Error in path program jump destination
Configurable
Cause
Jump to a positioning record outside the permitted range.
Measure
•
Check parameterisation.