7.2.5
Parameterise force/torque mode
The following settings can be parametrised in the Festo Configuration Tool (FCT):
Settings
Description
Analogue input
Scaling
Value for scaling (%) of the analogue setpoint value (±10 V) in a cur-
rent setpoint value (motor nominal torque).
Offset
Value for the height of the voltage shift “torque/force characteristic
curve” to the zero point
page 124.
Safe Zero
Threshold value for the analogue setpoint value range in which the
torque/force characteristic curve is valued as free of torque/force
(0 mA)
page 124.
Input malfunctions (e.g. offset fluctuations, noise, etc.) can be sup-
pressed or a defined rest of the drive can be parametrised.
If the motor controller can be operated via an external control circuit,
the value “0 V” should be parametrised as a Safe Zero to ensure the
stability of the external control circuit.
Tab. 7.2
Parameterise force/torque mode