![Festo CMMS-AS-G2 Series Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130116.webp)
7
Speed mode and force/torque mode
116
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
7.1.2
Function: speed mode
In the speed mode, the motor controller can be controlled via the active fieldbus (CANopen/
PROFIBUS DP/DeviceNet/RS485) or analogue input. Through the direct application (fieldbus) or the
analogue setpoint value (analogue input), the speed adjustment receives the speed setpoint value.
Optionally, the speed setpoint value ramp can be activated in the Festo Configuration Tool (FCT) to para-
meterise the acceleration and deceleration ramps for the positive/negative direction.
For speed mode, no homing is required.
7.1.3
Activate speed mode via fieldbus/analogue input
X4
CMMS-AS-...-G2
CANopen
PROFIBUS DP
RS485
Analogue input
Fieldbuses
Control section
X1
EXT
X5
DeviceNet
Input
Direct application
Analogue setpoint value
Speed setpoint
value ramp
Speed adjustment
Fig. 7.2
Overview: activate speed mode via fieldbus or analogue input