6
Positioning mode
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
81
6.5.3
Connection: digital inputs/outputs
Record selection bit 0 (DIN0)
Halt record sequence (DIN3)
Record selection bit 1 (DIN1)
Record selection bit 2 (DIN2)
NEXT2 (DIN11)
NEXT1 (DIN10)
Stop (DIN13)
24 V DC
Controller enable (DIN5)
Output stage enable (DIN4)
Common error (DOUT3)
2)
Controller ready for operation (DOUT0)
Motion complete (DOUT1)
2)
Start confirmed (DOUT2)
2)
CMMS-AS-...-G2
12
9
21
15
19
16
11
2
23
24
13
25
7
20
8
3
Limit switch 1 (DIN7)
1)
10
22
Limit switch 0 (DIN6)
1)
Mode bit 0 (DIN12)
Mode bit 1 (DIN9)
Start record sequence (DIN8)
X1
6
Load “DIN/DOUT” (GND 24 V)
Mode 2
The connection diagram shows the switch positions in operation.
1)
The limit switches are set by default to N/C contact (configuration over FCT)
2)
Default setting, freely configurable in the Festo Configuration Tool (FCT).
Fig. 6.12 Connection: digital inputs/outputs