![Festo CMMS-AS-G2 Series Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130068.webp)
6
Positioning mode
68
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
Parameters
Description
Command
(Sequence control
via NEXT1/2)
Condition for continuation in the sequence control:
NRI = with rising edge (NEXT…):
The current positioning record is interrupted immediately with the rising
edge (NEXT1/2), and the next positioning record (positioning record
parameter: target) is started.
NFI = with falling edge (NEXT…):
The current positioning record is interrupted immediately with the falling
edge (NEXT1/2), and the next positioning record (positioning record
parameter: target) is started.
NRS = with rising edge (NEXT…) and motion complete:
1) If a rising edge (NEXT1/2) is generated during travel of the current
positioning record, the next positioning record (positioning record
parameter: target) is started immediately after the target position (motion
complete = high) is reached.
2) If the current positioning record reaches the target position (motion
complete = high), the next positioning record (positioning record
parameter: target) is started with the next rising edge (NEXT1/2).
NFS = with falling edge (NEXT…) and motion complete:
1) If a falling edge (NEXT1/2) is generated during travel of the current
positioning record, the next positioning record (positioning record
parameter: target) is started immediately after the target position (motion
complete = high) is reached.
2) If the current positioning record reaches the target position (motion
complete = high), the next positioning record (positioning record
parameter: target) is started with the next falling edge (NEXT1/2).
Target
Subsequent positioning record in the record sequence.
This parameter is activated via the positioning parameter (FCT) “Command:
MC/STS/TIM/NRI/NFI/NRS/NFS”. All positioning records can be used as
subsequent positioning record in the record sequence.
Input
Continuation of sequence control via NEXT1/2 signal.
This parameter is activated via the positioning parameter (FCT) “Command:
NRI/NFI/NRS/NFS”. With the configured input (NEXT1/2), continuation can be
controlled in the sequence control.
Tab. 6.3
Overview: positioning record parameters