![Festo CMMS-AS-G2 Series Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130050.webp)
5
Commissioning and in operation
50
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
5.3.8
Download firmware file (xxx.S) (Memory card >> Motor controller)
Note
Loss of the motor controller parameters.
With a firmware download, all parameters of the motor controller are deleted (“factory
setting” status).
–
Back up the current parameters of the motor controller on a memory card before
conducting a firmware download (FCT: Controller >> SD). A parameter file is gener-
ated.
–
Load the parameter file after the firmware download from the memory card into the
motor controller (FCT: SD >> Controller).
Execute the following steps:
1. Make sure that the output stage enable signal (DIN4)[X1.21] = 0 V DC.
2. Shift the DIP switch [S1.8] to the “ON” position.
3. Insert the memory card with the firmware file (xxx.S) into the card slot [M1].
4. Switch the 24 V DC supply voltage off and then back on.
5. During booting, the motor controller checks (7-segments display: illuminated decimal point “.”)
whether a memory card is plugged into the card slot [M1].
If no memory card is plugged in, or it is damaged, the firmware version is loaded from the
permanent memory.
6. The firmware download is executed (7-segments display: flashing decimal point “.”) if a valid firm-
ware version is contained on the memory card.
No download is executed if the firmware version is the same or the firmware file is dam-
aged. The firmware version is then loaded from the permanent memory.
7. The newly loaded firmware starts automatically.
8. Shift the DIP switch [S1.8] to the “OFF” position.
Errors may occur in firmware download. Possible causes for this are:
–
Defective firmware file
–
Invalid firmware version
Errors are detected or triggered through the bootloader (7-segments display: illuminated
decimal point “.”).
Recommendation: Only one firmware file should be stored on the memory card. In the
case of several firmware files, the newest one is always loaded!