5.7.3
Configure data rate
The bit/transmission rate can be configured via the DIP switches [S1.9/S1.10].
Fieldbus
Bit/transmission rate
DIP switch
S1.10
S1.9
CANopen (CAN-Bus)/DeviceNet
125 KBit/s (125 kBaud)
OFF
OFF
250 KBit/s (250 kBaud)
OFF
ON
500 KBit/s (500 kBaud)
ON
OFF
CANopen (CAN bus)
1 MBit/s (1000 kBaud)
ON
ON
Tab. 5.6
Configure data rate
5.7.4
Configure fieldbus interface
The DIP switch [S1.11] may only be used for activating the CAN interface.
The fieldbus activation is dependent on the following points:
Fieldbus
Interface module
DIP switch
(mounted)
S1.11
CANopen
–
ON
DriveBus
–
ON
PROFIBUS DP
CAMC-PB
OFF
DeviceNet
CAMC-DN
OFF
RS485
–
OFF
Tab. 5.7
Configure fieldbus interface