3
Control interfaces
32
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
3.2
Analogue inputs/outputs [X1]
The motor controller CMMS-AS-...-G2 at the connection [X1] has a differential analogue input
(AIN0/#AIN0) and an analogue output (AMON0).
Overview: analogue input/output
Designation
Pin
Description
AIN0
(DIN12)
1)
2
Analogue input, differential
#AIN0
(DIN13)
1)
15
Analogue input, differential
+VREF
4
Reference voltage, 10 V DC
AGND
14
Analogue load, reference potential for analogue monitor, reference voltage
and analogue input
SGND
1
“Analogue signal” screening
AMONO
17
Analogue monitor (output)
1)
Multiple assignment of AIN0/#AIN0: These analogue inputs are used in the positioning mode/synchronisation as digital inputs for
mode bit 1 (DIN12) and stop signal (DIN13).
Tab. 3.5
Overview: analogue input/output
3.2.1
Analogue inputs (AIN0/#AIN0)
Function
Description
Analogue input, positive
(AIN0)[X1.2]
Differential analogue signal for control of the motor controller in the
speed mode or force/torque mode.
–
Positive setpoint value signal: max. ±10 V, 12 bit resolution
Analogue input, negative
(#AIN0)[X1.15]
Differential analogue signal for control of the motor controller in the
speed mode or force/torque mode.
–
Negative setpoint value signal: max. ±10 V, 12 bit resolution
Tab. 3.6
Function overview: analogue inputs
3.2.2
Analogue output (AMON0)
Function
Description
Analogue monitor
(AMON0)[X1.17]
The monitor output provides a configurable monitor signal (0…10 V)
with reference to the analogue load “AGND”.
Tab. 3.7
Function overview: analogue output