7
Speed mode and force/torque mode
118
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
7.1.5
Parameterise speed mode
The following settings can be parametrised in the Festo Configuration Tool (FCT):
Settings
Description
Analogue input
Scaling
Value for scaling (linear axis: mm/s or rotative axis: rpm) of the
analogue setpoint value (±10 V) in a speed setpoint value.
Offset
Value for the height of the voltage shift “rotational speed/speed
characteristic curve” to the zero point
page 119.
Safe Zero
Threshold value for the analogue setpoint value range in which the
rotational speed/speed characteristic curve is valued as rest (linear
axis = 0 mm/s or rotative axis = 0 rpm)
page 119.
Input malfunctions (e.g. offset fluctuations, noise, etc.) can be
suppressed or a defined rest of the drive can be parametrised.
If the motor controller can be operated via an external control circuit,
the value “0 V” should be parametrised as a Safe Zero to ensure the
stability of the external control circuit.
Setpoint value selection/speed setpoint value ramp
Ramp type
Selection of the ramp type
Dependent on the ramp type, the parameters “acceleration,
deceleration and positive/negative direction” can be parametrised
individually or grouped.
Acceleration
(positive/negative
direction)
Setpoint value for acceleration to the speed setpoint value.
Deceleration
(positive/negative
direction)
Setpoint value for deceleration to the speed setpoint value.
Tab. 7.1
Parameterise speed mode
Содержание CMMS-AS-G2 Series
Страница 1: ...Description Functions Firmware design from 1 4 0 2 6 8026161 1310NH Motor controller CMMS AS G2 ...
Страница 173: ......