Timing diagram: switch off motor controller via output stage enable signal
Controller enable
(DIN5)[X1.9]
Output stage enable
(DIN4)[X1.21]
Speed actual value
Holding brake released
(BR+)[X6.2]
Holding brake open
(mechanical)
t1
Controller ready for operation
(DOUT0)[X1.24]
t3
t4
t2
Output stage active
(DOUT… )[X1.…]
t1
≤
5 ms
t2
≤
2.5 ms
t3
L
50…500 ms
t4
= 0…6553 ms (FCT: dependent on the para-
metrised switch-off delay (brake control,
brake timing))
Fig. 5.11 Timing diagram: switch off motor controller via output stage enable signal
The holding brake is not suitable for braking the motor or moving masses.