![Festo CMMS-AS-G2 Series Скачать руководство пользователя страница 152](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130152.webp)
A
Diagnostic messages
152
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
Error group 29
SD card
No.
Reaction
Message
Code
29-2
7682h
SD parameter record error
Configurable
Cause
–
Checksum incorrect.
–
File not present.
–
File format incorrect.
–
Error backing up the parameter file on the SD card.
Measure
•
Check content (data) of the SD card.
Error group 31
I²t monitoring
No.
Code
Message
Reaction
31-0
2312h
I²t error motor (I²t at 100 %)
Configurable
Cause
I²t monitoring of the controller has been triggered.
–
Motor/mechanical system blocked or sluggish.
–
Motor under-sized?
Measure
•
Check motor and mechanical system.
31-1
2311h
I²t error controller (I²t at 100 %)
Configurable
Cause
I²t monitoring of the controller has been triggered.
Measure
•
Check power dimensioning of drive package.
Error group 32
Intermediate circuit
No.
Code
Message
Reaction
32-0
3280h
Intermediate circuit charging time exceeded
PS off
Cause
The intermediate circuit could not be charged after the mains
voltage was applied.
–
Fuse possibly defective.
–
Internal braking resistor defective.
–
In operation with external braking resistor, the resistor is not
connected
Measure
•
Check mains voltage (intermediate circuit voltage < 150 V)
•
Check interface to the external braking resistor.
•
If the interface is correct, the internal braking resistor or the
built-in fuse is presumably faulty
Repair by the manufac-
turer.
32-8
3285h
Power supply failure during controller enable
PS off
Cause
Interruption/power failure while the controller enable was active.
Measure
•
Check mains voltage/power supply.