![Festo CMMS-AS-G2 Series Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130113.webp)
6
Positioning mode
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
113
6.9.4
Timing diagram: teach
Teach
(DIN8)[X1.23]
Stop
(DIN13)[X1.15]
1) Jog+
2) Record selection bit 4
(DIN10)[X1.3]
1) Jog–
2) Record selection bit 5
(DIN11)[X1.16]
Motion complete
(DOUT1)[X1.12]
Controller ready for operation
(DOUT0)[X1.24]
Acknowledge teach
(DOUT2)[X1.25]
Common error
(DOUT3)[X1.13]
Speed
Jog+
Jog–
t1
t1
t2
t6
Record selection bit 0…3
(Positioning record 1…15)
(DIN…)[X1.…]
t2
t5
Store actual position
t3
t4
t3
t4
1) Jogging
2) Teaching
t7
t1
≤
5 ms
t2
≤
5 ms
t3
= … ms (FCT: dependent on the crawl
duration and jog acceleration ramp)
t4
= … ms (FCT: dependent on the jog
deceleration ramp)
t5
≤
2.5 ms
t6
= … ms (FCT: dependent on the debounce
time)
t7
≤
2.5 ms
Fig. 6.34 Timing diagram: teach