5
Commissioning and in operation
60
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
5.7
Fieldbus configuration (via DIP switches)
5.7.1
Overview of DIP switches [S1.1…12]
Fig. 5.13 Overview of DIP switches [S1.1...12]
5.7.2
Configure fieldbus address/MAC-ID
The address/MAC-ID can be configured via the DIP switches [S1.1…7].
Fieldbus
DIP switch
S1.7
S1.6
S1.5
S1.4
S1.3
S1.2
S1.1
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
2
6
= 64
2
5
= 32
2
4
= 16
2
3
= 8
2
2
= 4
2
1
= 2
2
0
= 1
CANopen
CAN address (1…127)
X
X
X
X
X
X
X
DriveBus
CAN address (2…13)
X
X
X
X
PROFIBUS DP
Bus address (3…126)
1)
X
X
X
X
X
X
X
DeviceNet
MAC-ID (0…63)
X
X
X
X
X
X
RS485
Address (0…127)
X
X
X
X
X
X
X
Example: address “57” =
(switch position)
+ 0
(OFF)
+ 32
(ON)
+ 16
(ON)
+ 8
(ON)
+ 0
(OFF)
+ 0
(OFF)
+ 1
(ON)
1)
The addresses “0…2” in Profibus DP are assigned to defined interfaces (e.g.: higher-order controller, etc.).
Tab. 5.5
Configure address of the fieldbus/MAC-ID