![Festo CMMS-AS-G2 Series Скачать руководство пользователя страница 115](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130115.webp)
7
Speed mode and force/torque mode
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
115
7
Speed mode and force/torque mode
7.1
Speed mode
7.1.1
Overview: speed mode (speed adjustment)
Current
regulator
Speed
regulator
Output stage
M
Motor
Encoder
Speed actual value
Current actual value
–
–
+
+
Speed setpoint value
Current setpoint
value
CMMS-AS-...-G2
Control section
Power section
Control interfaces
Speed setpoint value ramp
Fig. 7.1
Overview: speed mode (speed adjustment)
In the speed mode, the motor controller can be controlled via the fieldbus or analogue input. The regu-
lator cascade (speed and current regulator) processes the deviation “speed setpoint value” and “speed
actual value” and thus controls the following output stage. The speed setpoint value ramp can option-
ally be activated.