ProNet Plus Series AC Servo User's Manual
- 87 -
4.6.3 Setting the Electronic Gear
(1) Electronic Gear
The electronic gear enables the workpiece travel distance per input reference pulse from the host controller to be set to
any value.
One reference pulse from the host controller, i.e., the minimum position data unit, is called a reference unit.
When the Electronic Gear is Not Used
When the Electronic Gear is Used
workpiece
workpiece
No. of encoder
pulses
:
32768
Ball screw pitch
:
6mm
No. of encoder
pulses
:
32768
Ball screw pitch
:
6mm
One revolution is 6mm. Therefore 10÷6
=
1.6666 revolutions.
32768×4 pulses is one revolution.
Therefore, 1.6666×32768×4
=
218445
pulses. 218445 pulses are input as
reference pulses.
The equation must be calculated at the
host controller.
To move a workpiece 10mm :
The reference unit is 1µm. Therefore, to
move the workpiece 10mm (10000µm),
1pulse=1µm, so 10000/1
=
10000 pulses.
Input 10000 pulses per 10mm of
workpiece movement.
To move a workpiece 10mm using
reference units:
Reference unit
:
1µm