ProNet Plus Series AC Servo User's Manual
- 85 -
(6)Connection Example
The pulse train output form from the host controller corresponds to the following:
• Line-driver Output
• +24V Open-collector output
• +12V/+5V Open-collector output
(a)Connection Example for Line-driver Output
Applicable line driver: SN75174 manufactured by TI or MC3487 or the equivalent.
Host controller
Line-driver
*
Servodrive
Photocoupler
PULS
/PULS
30
31
150
Ω
CN1
SIGN
/SIGN
32
33
150
Ω
*
Represents twisted-pair wires
。
(b)Connection Example for Open-Collector Gate Output
NPN OC GATE OUTPUT
VDC
R
/SIGN
GND
75
Ω
2K
Ω
75
Ω
1CN-30
1CN-31
1CN-34
1CN-32
1CN-33
2K
Ω
R
SIGN
/PULS
PULS
NOTE:
VDC=12~24V
R=(VDC-1.5Volt)/10mA-150
VDC=12V,
R=1K
Ω /0.25W
VDC=24V,
R=2K
Ω /0.25W
75
Ω
75
Ω
Host controller
Servodrive
PNP OC GATE OUTPUT