5.2.6 Offset-adjustment of Servomotor Current Detection Signal
Automatic servomotor current detection offset adjustment is performed at ESTUN before shipping. Basically, the user
does not need to perform this adjustment.
Perform this adjustment only if highly accurate adjustment is required for reducing torque ripple caused by current offset.
This section describes the automatic and manual servomotor current detection offset adjustment.
Note:
·
Offset-adjustment of the servomotor current detection signal is possible only while power is supplied to the main
circuit power supply and with the servo is the OFF state.
·
Execute the automatic offset adjustment if the torque ripple is too big when compared with that of other servo
drives.
·
If this function, particularly manual adjustment, is executed carelessly, it may worsen the characteristics.
■
Automatic Offset-adjustment of Servomotor Current Detection Signal
Adjust the servomotor current detection signal automatically in the following procedure:
1. Press the MODE key to select the utility function mode.
2. Press the INC or DEC key to select the utility function number Fn005.
3. Press the ENTER key to enter into the automatic adjustment of the servomotor current detection signal mode.
4.Press the MODE key,the display will blinks for one second. The offset will be automatically adjusted.
5. Press the ENTER key to return to the utility function mode display Fn005.
Thus, the automatic offset-adjustment of the servomotor current detection signal is complete.
■
Manual Offset-adjustment of Servomotor Current Detection Signal
Adjust the servomotor current detection signal manually in the following procedure.
1. Press the MODE key to select the utility function mode.
2. Press the INC or DEC key to select the utility function number Fn006.
3. Press the ENTER key to enter into the manual adjustment of the servomotor current detection signal.