ProNet Plus Series AC Servo User's Manual
- 193 -
Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
t1
t2
PCON disabled
PCON enabled
PCON disabled
Reference pulse
Pn201
Electronic gear numerator 1
Pn203
Electronic gear numerator 2
Pn201
Electronic gear numerator 1
t1
,
t2>1ms
[1] Corresponding time sequence
t1
t2
PCON disabled
PCON enabled
PCON disabled
Reference pulse
Pn201
Electronic gear numerator 1
Pn203
Electronic gear numerator 2
Pn201
Electronic gear numerator 1
t1
,
t2>1ms
Time sequence when Pn002.0=0 or 1
t1
t2
PCON disabled
PCON enabled
PCON disabled
Reference pulse
t3
t4
Pn201
Electronic gear numerator 1
Pn203
Electronic gear numerator 2
Pn201
Electronic gear numerator 1
t1
,
t2
,
t3
,
t4>1ms
Error time sequence
t1
t2
PCON disabled
PCON enabled
PCON disabled
Reference pulse
Pn201
Electronic gear numerator 1
Pn203
Electronic gear numerator 2
Pn201
Electronic gear numerator 1
t1
,
t2>1ms
Pn002.1Reserved
Pn002.2 Absolute encoder selection
[0] Use absolute encoder as an absolute encoder
[1] Use absolute encoder as an incremental encoder
Pn002.3 Reserved
Pn003
Binary
After restart
ALL
Pn003.0 Reserved
Pn003.1Reserved
Pn003.2 Low speed compensation
[0] Without low speed correction
[1]With low speed correction to avoid servomotor
creeping, but the degree of correction is
determined by the setting in Pn129.
Pn003.3 Overload enhancement
[0] Without overload enhancement function
[1]With overload enhancement function, which can
enhance the overload capacity when servomotor
exceeds the 2 times rated overload. It is used in
frequent power ON/OFF occasions.
Содержание ProNet Plus Series
Страница 1: ...ProNet Plus Series AC Servo User s Manual Version V1 05...
Страница 216: ......