![Estun ProNet Plus Series Скачать руководство пользователя страница 205](http://html1.mh-extra.com/html/estun/pronet-plus-series/pronet-plus-series_user-manual_2429757205.webp)
ProNet Plus Series AC Servo User's Manual
- 203 -
Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
Pn402
Reverse torque
internal limit
Immediately
P, S, T
Pn403
Forward external
torque limit
Immediately
P, S, T
Pn404
Reverse external
torque limit
Immediately
P, S, T
Pn405
Plug braking torque
limit
Immediately
P, S, T
Pn406
Speed limit during
torque control
Immediately
T
Servomotor output torque limit value during torque
control Unit: rpm
Pn407
Notch filter 1
frequency
Immediately
P, S, T
Notch filter 1 frequency
Unit:Hz
1. In some conditions,
vibration will be picked
up and response will be
lagged after notch filter
is set.
2. When notch filter
frequency is set to
5000, the notch filter is
invalid.
Pn408
Notch filter 1 depth
Immediately
P, S, T
Notch filter 1 depth
Pn409
Notch filter 2
frequency
Immediately
P, S, T
Notch filter 2 frequency
Unit:Hz
Pn410
Notch filter 2 depth
Immediately
P, S, T
Notch filter 2 depth
Pn411
Low frequency
vibration frequency
Immediately
P, S
Frequency of low frequency vibration with load.
Unit:0.1Hz
Pn412
Low frequency
vibration damp
Immediately
P, S
Attenuation damp of low frequency vibration with load.
Pn413
Torque control delay
time
Immediately
T
These parameters are only enabled in position control
mode.
Pn414
Torque control speed
hysteresis
Immediately
T
Pn415
Analog torque given
zero bias
Immediately
T
This parameter is used to set zero bias of analog
torque given, and it is related with torque reference
input gain (Pn400),
Analog torque reference=( Torque reference input
analog voltage
—Analog torque reference zero
bias)×Analog torque reference input gain. Unit:10mv
Pn416
Reserved
—
—
—
Pn500
Positioning error
Immediately
P
Outputs /COIN signal when error counter is less than
this value.Unit:puls
Pn501
Coincidence
difference
Immediately
P
Outputs /VCMP signal when the difference between
speed reference value and speed feedback value is
less than this value. Unit: rpm
Pn502
Zero clamp speed
Immediately
S
The servomotor is locked when the speed
corresponding to the analog input is less than this
value. Unit: rpm
Pn503
Rotation detection
speed
Immediately
P, S, T
When the servomotor speed exceeds this parameter
setting value, it means that the servomotor has