ProNet Plus Series AC Servo User's Manual
- 196 -
Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
[C]Position control(contact reference)
PCON: Used to change step
PCL, NCL: Used to search reference point or start
[D]Speed control(parameter reference)
PCON invalid
Pn005.2 Out-of-tolerance alarm selection
[0]Out-of-tolerance alarm disabled
[1]Out-of-tolerance alarm enabled. Outputs alarm
when the value of error counter exceeds Pn504
setting value.
[2] Reserved
[3] Reserved
Pn005.3 Reserved
Pn006
Hex
After restart
P, S
Pn006.0 Bus type selection
[0]No bus
[1]PROFIBUS-DP V0/V1
[2]PROFIBUS-DP V2
[3] CANopen
[4] EtherCAT
Pn006.1 Reserved
Pn006.2 Low-frequency vibration suppression
switch
[0]Low-frequency vibration suppression function
disabled
[1]Low-frequency vibration suppression function
enabled
Pn006.3 Reference input filter for open collector
signal
[0] When pulse is difference input, the max value of
servo receiving pulse frequency≤4M
[1] When pulse is difference input, the max value of
servo receiving pulse frequency ≤650K
[2] When pulse is difference input, the max value of
servo receiving pulse frequency≤150K
Notes: “the max value of servo receiving pulse
frequency” ,it means the sufficient max value of pulse
frequency receiving by servo hardware.
Pn007
Binary
After restart
ALL
Pn007.0: Wider the width of C pulse or not
[0] Standard width of C pulse
[1] Wider the width of C pulse
Pn007.1: Reserved
Pn007.2: Reserved
Pn007.3: Torque filter
[0] Standard torque filter
Содержание ProNet Plus Series
Страница 1: ...ProNet Plus Series AC Servo User s Manual Version V1 05...
Страница 216: ......