ProNet Plus Series AC Servo User's Manual
- 170 -
Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
[1] New torque filter
Pn008
Reserved
—
—
—
Pn009
Binary
After restart
P
Pn009.0:Reserved
Pn009.1:Reserved
Pn009.2:Electronic gear selection
[0] 16 bit electronic gear
[1] 32 bit electronic gear
Pn009.3:Reserved
Pn010
Hex
After restart
P, S, T
Pn010.0: Automatic identification motor function
enabled
[0] Disabled auto identity function
[1] Enabled auto identity function (get the models of
servo drive, servo motor, encoder automatically, and
load the servo drive parameters, but not read the
motor parameters from Pn parameters.
Pn010.1: Reserved
Pn010.2: Reserved
Pn010.3: Reserved
Pn100
Online autotuning
After restart
P, S
Pn100.0 Load inertia setting
[0] Manual setting
[1,2,3] Normal mode
[4,5,6] Vertical load
[1,4] Load inertia without variation
[2,5] Load inertia with little variation
[3,6] Load inertia with great variation
Pn100.1 Online autotuning setting
[0] Manual setting
[1] Standard
[2] Steadily
[3] High precision
Note:
Autotuning may be invalid in the following cases:
1.Autotuning is invalid when servomotor max.speed is
less than 100rpm.
2.Autotuning is invalid when servomotor acceleration
/deceleration
speed
is
less
than
5000rpm/s.
3.Autotuning is invalid when mechanical clearance is
too big during operation.4.Autotuning is invalid when
the difference of different speed load is too great.
4.Autotuning is invalid when mechanical vibration and
friction are too big during operation.