![Estun ProNet Plus Series Скачать руководство пользователя страница 138](http://html1.mh-extra.com/html/estun/pronet-plus-series/pronet-plus-series_user-manual_2429757138.webp)
ProNet Plus Series AC Servo User's Manual
- 136 -
11-bit character form (8-bit data)
Start
bit
0
1
2
3
4
5
6
Stop
bit
8-data bits
11- bits character frame
8
,
N
,
2
(
Modbus
,
ASCII / RTU
)
Stop
bit
7
Start
bit
0
1
2
3
4
5
6
Even
parity
8-data bits
11- bits character frame
8
,
E
,
1
(
Modbus
,
ASCII / RTU
)
Stop
bit
7
Start
bit
0
1
2
3
4
5
6
Odd
parity
8-data bits
11- bits character frame
8
,
O
,
1
(
Modbus
,
ASCII / RTU
)
Stop
bit
7
Communication protocol structure:
Data format of communication protocol:
ASCII Mode:
STX
Start character
‘: ’
=>
(3A
H
)
ADR
Communication address
=>
1-byte contains two ASCII codes
CMD
Reference code
=>
1-byte contains two ASCII codes
DATA(n-1)
Data content
=>
n-word=2n-byte contain 4nASCII codes, n
≦
12
……
DATA(0)
LRC
Checking code
=>
1-byte contains two ASCII codes
End 1
End code 1
=>
(0D
H
) (CR)
End 0
End code 0
=>
(0A
H
) (LF)
RTU Mode:
STX
Sleep interval of at least 4 bytes transmission time.
ADR
Communication address
=>
1-byte
CMD
Reference code
=>
1-byte
DATA(n-1)
Data content
=>
n-word=2n-byte, n
≦
12
……
DATA(0)
CRC
CRC checking code
=>
1-byte
End 1
Sleep interval of at least 4 bytes transmission time.
Communication protocol data format instructions are as follows:
STX (communication start)
ASCII mode:
‘: ’character