Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
Pn509
Allocate input signal
to terminal
After restart
P, S, T
Pn509.0 → CN1_14
Pn509.1 → CN1_15
Pn509.2 → CN1_16
Pn509.3 → CN1_17
Pn510.0 → CN1_39
Pn510.1 → CN1_40
Pn510.2 → CN1_41
Pn510.3 → CN1_42
Terminal PRI is CN1_14< CN1_15< CN1_16<
CN1_17< CN1_39< CN1_40< CN1_41< CN1_42
Corresponding signal of each data is shown as
following:
[0]S-ON
[1]P-CON
[2]P-OT
[3]N-OT
[4]ALMRST
[5]CLR
[6]P-CL
[7]N-CL
[8]G-SEL
[9]JDPOS-JOG+
[A]JDPOS-JOG-
[B]JDPOS-HALT
[C]HmRef
[D]SHOM
[E]ORG
[F]ZCLAMP
Pn510
Allocate input signal
to terminal
After restart
P, S, T
Pn511
Allocate output signal
to terminal
After restart
P, S, T
Pn511.0 → CN1_11, CN1_12
Pn511.1 → CN1_05, CN1_06
Pn511.2 → CN1_09, CN1_10
Corresponding signal of each data is shown as
follows:
[0]COIN/VCMP
[1]TGON
[2]S-RDY
[3]CLT
[4]BK
[5]PGC
[6]OT
[7]RD
[8]HOME
[9]TCR
[A]R-OUT1