Technical data
Proline t-mass 65 PROFIBUS DP
94
"
Caution!
The flowrates shown are representative of the calibrated conditions only and do not necessarily
reflect what the meter can measure under operating conditions and actual internal pipe dimensions
found on site. To correctly size and select a meter, it is recommended that you either contact your
local Hauser representative or refer to Applicator (the Hauser sizing and selection
software).
Examples in metric units:
Examples in US units:
10.1.4
Output
Output signal
PROFIBUS DP interface:
• PROFIBUS DP in accordance with IEC 61158, galvanically isolated
• Profile Version 3.0
• Data transmission rate: 9.6 kBaud to 12 MBaud
• Automatic identification of data transmission rate
• Signal coding: NRZ code
• Fieldbus address can be configured via miniature switches, via operating program or via the local
display (optional)
Signal on alarm
Status and alarm messages in accordance with PROFIBUS Profile Version 3.0
Low flow cut off
Switch points for low flow cut off are programmable.
Galvanic isolation
All circuits for inputs, outputs and power supply are galvanically isolated from each other.
10.1.5
Power supply
Electrical connections
Supply voltage
85 to 260 V AC, 45 to 65 Hz
20 to 55 V AC, 45 to 65 Hz
16 to 62 V DC
Line Size
Gas
Process pressure
Temperature
Max. Flowrate
DN
bar a
°C
kg/h
50
Air
1
25
910
50
Air
3
25
3300
50
CO
2
1
25
1300
50
CO
2
3
25
3950
50
Methane
1
25
795
50
Methane
3
25
1500
Line Size
Gas
Process pressure
Temperature
Max. Flowrate
DN
psi a
°F
lb/hr
2"
Air
14.7
77
2002
2"
Air
44.1
77
7260
2"
CO
2
14.7
77
2860
2"
CO
2
44.1
77
8690
2"
Methane
14.7
77
1749
2"
Methane
44.1
77
3300