Installation
Proline t-mass 65 PROFIBUS DP
24
3.2.15
Thermal insulation
When the gas is very humid or saturated with water (eg. Bio Gas) the pipeline and flowmeter body
should be insulated to prevent water droplets condensing on the pipe wall and/or flow transducer.
In extreme cases of moisture and temperature variation, it may be advisable to provide trace heating
of the pipework and/or sensor body.
a0005122
Fig. 15:
Maximum thermal insulation for t-mass 65F and 65I
a = Maximum insulation height for the flanged version
b = Maximum insulation height for the insertion version
3.2.16
Vibrations
"
Caution!
Excessive vibration can result in mechanical damage to the measuring device and its mounting.
Observe the vibration specification in the technical data section
a
b
a
b