6.3.3
Data back-up with T-DAT SAVE/LOAD function
The T-DAT SAVE/LOAD function can be used to store all the settings and parameters of the
device to the HistoROM/T-DAT data storage device.
A0001221-EN
Fig. 33:
Data back-up with T-DAT SAVE/LOAD function
Accessing T-DAT function
The T-DAT SAVE/LOAD function is accessed via the QUICK SETUP function.
• Press
F
until the prompt “QS-COMMISSION NO” appears.
• Press
F
until “QS-COMMUNICATION NO” appears.
• Press
F
and the prompt “T-DAT SAVE/LOAD CANCEL” appears.
• Press
O
or
S
key and the device access code entry appears.
• Enter the device access code “65” and Press
F
; programming is enabled
• Use
O
or
S
key to select the following options:
– LOAD
Data on the HistoROM/T-DAT data storage device are copied to the device memory (EEROM).
This overwrites any settings and parameters of the device. The measuring device is restarted.
– SAVE
Settings and parameters are copied from the device memory (EEPROM) to the
HistoROM/T-DAT.
– CANCEL
Cancels the option selection and returns you to the higher selection level.
Application examples
• After commissioning, the current measuring point parameters can be saved to the
HistoROM/T-DAT as a backup.
• If the transmitter is replaced for some reason, the data from the HistoROM/T-DAT can be loaded
into the new transmitter-EEPROM.
!
Note!
• If the target device has an older software version, the message #042 “TRANSM.SW-DAT” is
displayed during startup. Then only the SAVE option is available.
• LOAD
→
This option is only possible if the target device has the same software version as,
or a more recent software version than, the source device
• SAVE
→
This option is always available.
+
+
E
Esc
E
+
-
XXX.XXX.XX
+
E
T-DAT
SAVE/LOAD
Quick Setup
HOME
POSITION
LOAD
YES
NO
Sure ?
CANCEL
SAVE
YES
NO
Sure ?
Restart of the
measuring device
Input is
saved